Building Engineering Specialist
Ahli Muda Teknik Bangunan Gedung
- Issuer
- BNSP, Indonesia Professional Certification Authority
- Agency
- Tenaga Konstruksi Nasional
A two-storey Javanese modern house on a 10 × 20 m plot, drawn the Indonesian way: metres, a symmetric column grid of two 4,00 m bays, 30/30 columns for an earthquake zone.
The ground floor rises from its plan: pendopo, pringgitan, an open dalem with the kitchen and dining, and a stair of 20 risers with its landing over the storeroom.
The upper slab lands on the frame, open over the stair. A concrete shear wall on the east side balances the walls on the west.
A master bedroom, two children's rooms and a floor-sitting santai that is also the musholla, facing the qibla on its solid west wall.
A two-tier limasan over the house and a joglo with its tumpang sari over the pendopo, standing free of the house on its own soko guru.
Garden, fence and regol, the water tower on its own braced frame. Drag to turn the house, or keep scrolling.
Scroll
Led multidisciplinary engineering teams delivering full-lifecycle infrastructure projects on time and within budget: structural design, DED review, standardized budgeting frameworks, and rigorous technical audits. The kind of engineering where mistakes are very visible and very permanent.

Both issued by BNSP (Badan Nasional Sertifikasi Profesi), Indonesia's national professional certification authority.
Ahli Muda Teknik Bangunan Gedung
Ahli Muda K3 Konstruksi
Dinas CIKASDA, Sulawesi Tengah
Led multidisciplinary teams delivering full-lifecycle infrastructure projects, on schedule, inside budget, planning through handover.
Standardized budgeting frameworks so cost estimates became a repeatable method rather than one engineer's spreadsheet.
Technical audits of designs and consultancy deliverables: the review seat, where you learn what actually goes wrong.
Tadulako University, Palu
Palu is a high-seismicity city that lived through the 2018 earthquake and tsunami. You do not study structures there abstractly.
Concrete design to SNI 2847, wind load analysis to SNI 1727, seismic mode translation to SNI 1726, steel slenderness and stress-ratio checks, composite bondek floor slabs, including a project in Palu, where seismic detailing is not a formality.
Abutment capacity checks, vertical deflection control to SNI, elastomer bearing pad design, and the joint details where bridges actually fail.
Site supervision and construction occupational safety (K3) management to SNI standards, certified, and applied on live sites where the consequences are immediate.
DED review, ANDALALIN traffic impact documents, environmental impact assessments, consultancy reporting for BGN, and procurement red-flag analysis on LPSE tenders. The unglamorous half of civil engineering, and the half that decides whether a project survives audit.
Counted straight from the project log: public buildings, offices, sports facilities, roads, drainage, and landscape works.